from Chesterton Posted 10-12-03  STATIONARY - CENTERED ROTARY - MISCENTERED
SYMPTOMS: Centered or miscentered CAUSES: Centered seal face wear track indicates - Properly centered seal and good equipment operation Miscentered seal face wear track indicates Miscentered seal (rotary type) during installation Equipment condition - Radial runout Equipment operation - Off curve, vibration FAILURE MODES: Misinstallation Equipment conditions SOLUTIONS: Check bearings for radial runout exceeding limit of seal type Review installation techniques/instructions Check equipment for shaft - Seal chamber concentricity
|
|